Widgets Help Feedback To bookmarks
Strip foundation Slab foundation Column foundation
Frame house Bricks Building blocks Foam blocks Aerated blocks Ceramic blocks Wooden beams Wooden logs
Lean-to roof
Metal sheet fence Picket fence
Underfloor heating
Electrical cable Heavy concrete Light concrete Mortar Insulation Floor materials

Online calculator for calculating a lean-to roof, slope angle and number of roof battens

Lean-to roof
Width of the roof base excluding overhang.
The units of measurement are meters.
Base width A
meters
The length of the roof base without taking into account the overhang.
The units of measurement are meters.
Base length D
meters
The height of the rise from the beginning of the laying of the roof to the ridge.
The units of measurement are meters.
Lifting height B
meters
The protrusion of the ends of the rafters beyond the outer surface of the wall. The recommended minimum value is 0.3 meters, to prevent precipitation from falling on the surface of the walls.
The units of measurement are meters.
Left Overhang of the cornice K1
meters
The protrusion of the ends of the rafters beyond the outer surface of the wall. The recommended minimum value is 0.3 meters, to prevent precipitation from falling on the surface of the walls.
The units of measurement are meters.
Right Overhang of the cornice K2
meters
The projection of the end cornice beyond the outer surface of the wall. The recommended minimum value is 0.3 meters, to prevent precipitation from falling on the surface of the walls.
The units of measurement are meters.
Ledge from the left end T1
meters
The projection of the end cornice beyond the outer surface of the wall. The recommended minimum value is 0.3 meters, to prevent precipitation from falling on the surface of the walls.
The units of measurement are meters.
Ledge from the right end T2
meters
General information
Roof pitch
The angle of inclination is suitable for the selected material.
18.43 degrees
Roof surface area 25.05 m2
Approximate max load per 1m2 of roof 201.72 kgf/m2
Roof weight excluding climatic loads 644 kg
Roof weight taking into account climatic loads 5052 kg
Rafters
The actual length of the rafters 3845 mm
The minimum size of the rafters at the spacing 600 mm
and length 3000 mm in span
50 x 144.1 mm
Suitable size of rafters 50 x150 mm
Safety margin 4.1 %
Number of rafters 11 pcs
Load per 1 meter of rafters 121.03 kg
Total length of the rafters 42.3 meters
The volume of the rafters 0.32 m3
Weight of rafters 190.33 kg
Mauerlat size 150 x 150 mm
Roof battens
The distance between the rows of the roof battens 200 mm
The number of rows of roof battens 12 rows
The number of roof battens boards in length 6 meters 12 pcs
The volume of the roof battens 0.27 m3
Weight of the roof battens 162 kg
Materials
Number of sheets of roofing material 11 pcs
The number of fasteners is 8 pieces per 1m2 201 pieces
Weight of roofing material 150.27 kg
Insulation volume 3.8 m3
Number of rolls of steam-waterproofing with overlap 200 mm 1 pcs

Information on the purpose of the calculator

Please report any errors found by feedback by copying the link to the calculation.

The online single-pitched roof calculator is designed to calculate the slope angle, quantity and size rafters, the number of crates, as well as the volume of necessary materials. The calculations take into account all popular roofing materials such as ceramic, cement-sand, bitumen and metal tiles, ondulin, slate, etc. It is possible to calculate a flat roof according to the specified parameters. The calculation is accompanied by drawings in different projections, and a drawing of the rafters with the dimensions of the lower saw.

The single-pitched roof is the simplest among other types of roofs and economical in terms of consumption of materials and works, as it has only one ramp. This type of roof is quite popular and mostly it is used for garages, outbuildings and other non-residential premises. It can be both attic and heartless.

For this roof, almost all popular types of roofing, under-roofing are applicable materials and insulation materials. Various slope angles are applicable to this type of roof, but most often small angles are used. In this case, it is necessary to take into account the increased snow loads on the roof and clean it from snow in a timely manner.

When filling in the data, pay attention to the additional information with the Additional information

The following is a complete list of calculations performed with a brief description of each item.

General information on the results of calculations

C ( ) / 7 8 9 x 4 5 6 + 1 2 3 - . 0 =